Insulation R-Value Calculator

Add up layered materials into one R-value and compare it with a target.

Your numbers

Layers
Layer 1
Layer 2

With a temperature difference, shows the heat flow through this area.

Inside minus outside.

Result

Total R-value

R-18

2 layers added together

Total R-value
18
U-factor (1 / R)
0.0556
Layers
2

Layers

LayerR-valueShare
Fiberglass batt1372.2%
Foam board527.8%
Total18100%
How this was calculated
  1. Layers stacked one behind the other add their R-values: total R = R1 + R2 + R3 and so on.
  2. Total R = 13 + 5 = 18. U-factor = 1 / 18 = 0.0556.
  • R-values add up only for layers in series. Studs, joists and other framing let heat bypass the insulation, so a whole wall performs worse than the cavity alone. Air gaps, air films, moisture, compression and air leaks are not modeled, and the R-values are whatever you enter. This is not an energy code or engineering calculation.

Calculated using SumPanda.com · https://sumpanda.com/r-value-calculator/

Results are estimates for general information. Verify important figures before relying on them.

Next step

How to use the insulation r-value calculator

  1. List each layer of the wall, roof or floor with a name.
  2. For each layer enter its R-value, or its thickness and R per inch if only those are known.
  3. Optionally enter a target R-value, an area and a temperature difference.
  4. Read the total R-value, the U-factor, how each layer contributes and the heat flow.

Formula

Total R = R1 + R2 + R3 + ... for layers one behind another

Layer R = thickness x R per inch, when the R-value of the layer is not given

U-factor = 1 / total R

Heat flow in BTU per hour = area x temperature difference / total R

Adding R-values works only for layers in series. Heat that travels around the insulation through framing is not included.

R-13 batt plus R-5 foam board

A fiberglass batt of R-13 and a foam board of R-5 give a total of R-18. The batt supplies 72.2% of it and the foam 27.8%. The U-factor is 1 / 18 = 0.0556.

Across 1,000 square feet with a 40 degree temperature difference, the heat flow is 1,000 x 40 / 18 = 2,222.2 BTU per hour. If your goal was R-30, the assembly falls short by 12. Entering a layer as 3.5 inches at R 3.7 per inch gives R-12.95 for that layer, and the example values are not recommendations.

Series and parallel paths

Insulation in a wall does not cover everything. Studs and joists let more heat through than the cavity does, so the whole wall performs worse than the cavity R-value alone suggests. This tool adds layers in series only, so treat the result as an upper bound for a framed assembly.

To find how much material a target needs, use the insulation calculator. To see what heat loss costs in energy, the electricity cost calculator is a next step.

What the U-factor is

The U-factor is the reverse of R: how much heat passes per hour per square foot per degree of temperature difference. Windows are usually rated by U-factor and walls by R-value, so converting helps compare them. A lower U-factor means a better barrier.

The heat flow shown is a steady state estimate for a constant temperature difference. Real buildings also gain and lose heat through air leaks, sunlight and ventilation. Read about those costs in the solar payback calculator.

Assumptions and limits

  • Every R-value, thickness and R per inch is whatever you enter. Nothing is built in.
  • Layers are in series and the whole area has the same layers.
  • Air films, air gaps, moisture, compression and air leakage are not modeled.
  • This is not an energy code or engineering calculation.

Formulas reviewed October 10, 2026. See the calculation methodology for how SumPanda rounds, tests and sources its formulas.

Frequently asked questions

How do I add R-values?

Add the R-values of each layer in the path of the heat. R-13 plus R-5 is R-18.

How do I find the R-value from thickness?

Multiply the thickness in inches by the R-value per inch for that material. A layer that is 3.5 inches at 3.7 per inch is 12.95.

What is the U-factor?

It is one divided by the total R-value. It measures how fast heat passes through, so a lower number is better.

Why is a real wall worse than the total here?

Framing carries heat around the insulation, so the average over the whole wall is lower than the R-value of the cavity alone.